An interface for your team
Operator views, measurement areas, thresholds and dashboards designed around your equipment and teams.


Fixed-mount thermal camera. Monitor temperatures continuously, right inside your installation.
Depending on model and configuration. Accuracy: whichever value is greater. The 2,000 °C range is available on CH models.
Measure. Monitor. Integrate.
Installed at a fixed position, the 600 Series tracks thermal changes in equipment and processes. Radiometric images provide temperature data for analysis, beyond visual inspection.
A closer look
Explore the housing, optics and format of the 600 Series.
Monitor temperatures continuously with the 600 Series and tailor alerts to your process.
Technical specifications
The series covers several resolutions and temperature ranges. NetForge helps you select the model and plan its integration.
| Model | IR resolution | Max. temperature | Focus |
|---|---|---|---|
| 628CH | 640 × 480 | 2 000 °C | Automatic |
| 626CH | 384 × 288 | 2 000 °C | Automatic |
| 628C | 640 × 480 | 650 °C | Automatic |
| 626C | 384 × 288 | 650 °C | Automatic |
| 625C | 320 × 240 | 350 °C | Automatic |
| 618C | 640 × 480 | 650 °C | Manual |
| 616C | 384 × 288 | 650 °C | Manual |
| 615C | 320 × 240 | 350 °C | Manual |
| 613C | 160 × 120 | 350 °C | Manual |
Measurement ranges start at −20 °C and are divided into several ranges. Lenses and minimum focus distances depend on the configuration. See the datasheet for details.
FOTRIC camera. NetForge development.

Custom development is part of our support. We use the FOTRIC SDK and API to adapt the software and camera workflows to your use case.
From camera control to measurement analysis, NetForge can build the application that connects thermal images to your teams’ decisions.
Operator views, measurement areas, thresholds and dashboards designed around your equipment and teams.
Temperature acquisition, history and connections to your monitoring system or existing software.
Alerts, image capture, reports and multi-camera monitoring based on your operating rules.
Together, we define the functions and integrations to develop within the scope of your project.
| Specification / model | 628CH | 626CH | 628C | 626C | 625C | 618C | 616C | 615C | 613C |
|---|---|---|---|---|---|---|---|---|---|
| Detector & optics | |||||||||
| Thermal resolution (pixels) | 640 × 480 | 384 × 288 | 640 × 480 | 384 × 288 | 320 × 240 | 640 × 480 | 384 × 288 | 320 × 240 | 160 × 120 |
| Detector type | Uncooled focal plane array | ||||||||
| Thermal sensitivity (NETD) | < 30 mK | < 50 mK | < 30 mK | < 50 mK | < 50 mK | < 30 mK | < 50 mK | < 50 mK | < 60 mK |
| Detector pitch | 17 µm | ||||||||
| Spectral range | 7.5–14 µm | ||||||||
| Field of view (FOV) | Depends on lens configuration | ||||||||
| Instantaneous field of view (IFOV) | Depends on lens configuration | ||||||||
| Minimum focus distance | Depends on lens configuration | ||||||||
| Focal length | Depends on lens configuration | ||||||||
| Focus | Automatic | Manual | |||||||
| Measurement & analysis | |||||||||
| Temperature ranges | −20 to 150 °C 0 to 650 °C 300 to 2,000 °C | −20 to 150 °C 0 to 650 °C 300 to 2,000 °C | −20 to 150 °C 0 to 650 °C | −20 to 150 °C 0 to 650 °C | −20 to 150 °C 0 to 350 °C | −20 to 150 °C 0 to 650 °C | −20 to 150 °C 0 to 650 °C | −20 to 150 °C 0 to 350 °C | −20 to 150 °C 0 to 350 °C |
| Accuracy | ±2 °C or ±2%, whichever is greater | ||||||||
| Measurement parameters | Emissivity; ambient temperature; reflected temperature; relative humidity; distance; external optics compensation | ||||||||
| Partial emissivity | Supported | ||||||||
| Measurement tools | 5 points, 10 lines, 10 areas; Modbus output | ||||||||
| Image & software | |||||||||
| Palettes | 10 standard and 10 inverted palettes | ||||||||
| Image processing | Non-uniformity correction and digital enhancement | ||||||||
| Mirror modes | Left–right, up–down, centre | ||||||||
| Video compression | H.264 | ||||||||
| Radiometric stream | Supported | ||||||||
| PTZ compatibility | Pelco-D protocol | ||||||||
| Software | AnalyzIR ; Open API FOTRIC SDK | ||||||||
| Network & interfaces | |||||||||
| Ethernet | 10 / 100 / 1 000 Mbit/s | ||||||||
| Network protocols | IPv4, UDP, TCP, RTSP, RTCP, RTP | ||||||||
| Simultaneous streams | Main and substream: 10; radiometric stream: 1 | ||||||||
| IP connection interface | ONVIF | ||||||||
| Network connector | Screw-on RJ45 with LED indicator | ||||||||
| Serial port | RS-485 | ||||||||
| Relay output | 1 × 24 V / 1.5 A | ||||||||
| Optocoupler output | 1 × 3.3–24 V ; 35 mA max. | ||||||||
| Optocoupler input | 1 × 3.3–24 V ; 5–15 mA | ||||||||
| Power | |||||||||
| Power supply | 12 / 24 V DC or PoE | ||||||||
| Power connector | Screw terminal | ||||||||
| Power consumption | 4 W | 3 W | 4 W | 3 W | 3 W | 4 W | 3 W | 3 W | 3 W |
| Environment & construction | |||||||||
| Protection rating | IP40 | ||||||||
| Operating temperature | −20 to +65 °C | ||||||||
| Storage temperature | −40 to +70 °C | ||||||||
| Relative humidity | < 90 % | ||||||||
| Shock resistance | 25 g per IEC 60068-2-27:2008 | ||||||||
| Vibration resistance | 2 g per IEC 60068-2-6:2007 | ||||||||
| Housing material | Aluminium alloy | ||||||||
| Dimensions (mm) | 164.6 × 80 × 79 standard lens | 157.25 × 80 × 79 standard lens | 142.25 × 71 × 70 standard lens | 112 × 68 × 60 without lens | |||||
| Weight (g) | 993 standard lens | 713 standard lens | 718 standard lens | 706 standard lens | 485 without lens or base | ||||